In caso di Virtualizzazione di un Sistema Windows SBS 2008 o SBS 2011 e si presenti l’errore 0x0000007B e un continuo riavvio del sistema, dovremo procedere come segue:


Montare il VHD ed esaminarne il contenuto

Verifica la presenza dei seguenti File:

  • ?:\windows\system32\drivers\intelide.sys
  • ?:\windows\system32\drivers\pciide.sys
  • ?:\windows\system32\drivers\atapi.sys

Aprire il Registro di sistema e caricare l’Hive SYSTEM del disco VHD appena montato (?:\windows\system32\config\system) e chiamarlo VM

Verifica l’esistenza delle seguenti chiavi e eventualmente modificarne i valori come descritto:

  • HKEY_LOCAL_MACHINE\VM\ControlSet001\Control\CriticalDeviceDatabase\pci#ven_8086&dev_7110&cc_0601
    • “ClassGUID”=”{4D36E96A-E325-11CE-BFC1-08002BE10318}”
    • “Service”=”intelide”
  • HKEY_LOCAL_MACHINE\VM\ControlSet001\Control\CriticalDeviceDatabase\pci#ven_8086&dev_7111
    • “ClassGUID”=”{4D36E96A-E325-11CE-BFC1-08002BE10318}”
    • “Service”=”intelide”
  • HKEY_LOCAL_MACHINE\VM\ControlSet001\Control\CriticalDeviceDatabase\primary_ide_channel
    • “Service”=”atapi”
    • “ClassGUID”=”{4D36E96A-E325-11CE-BFC1-08002BE10318}”
  • HKEY_LOCAL_MACHINE\VM\ControlSet001\Control\CriticalDeviceDatabase\secondary_ide_channel
    • “Service”=”atapi”
    • “ClassGUID”=”{4D36E96A-E325-11CE-BFC1-08002BE10318}”
  • HKEY_LOCAL_MACHINE\VM\ControlSet001\Services\IntelIde
    • “ErrorControl”=dword:00000001
    • “Group”=”System Bus Extender”
    • “Start”=dword:00000000
    • “Tag”=dword:00000004
    • “Type”=dword:00000001
  • HKEY_LOCAL_MACHINE\VM\ControlSet001\Services\PCIIde
    • “ErrorControl”=dword:00000001
    • “Group”=”System Bus Extender”
    • “Start”=dword:00000000
    • “Tag”=dword:00000003
    • “Type”=dword:00000001
    • “DisplayName”=”Standard IDE/ESDI Hard Disk Controller”
  • HKEY_LOCAL_MACHINE\VM\ControlSet001\Services\atapi
    • “ErrorControl”=dword:00000001
    • “Group”=”SCSI miniport”
    • “Start”=dword:00000000
    • “Tag”=dword:00000019
    • “Type”=dword:00000001
    • “DisplayName”=”Standard IDE/ESDI Hard Disk Controller”